Here, we report the case of an intraorbital intraconal foreign body that was successfully retrieved by a transnasal endoscopic approach facilitated intraoperatively by a magnetic stick. A 36-year-old man was admitted to our unit with a left-sided intraorbital intraconal metallic foreign body. Following 2 failed attempts via a transconjunctiva approach, we finally recovered the foreign body using transnasal endoscopic surgery. During this procedure, a magnetic stick was used to help us locate and successfully remove the foreign body, grapeshot measuring approximately 0.5 cm in diameter. Visual acuity in the injured eye increased from 0.01 preoperatively to 0.04 6 days after surgical intervention. There were no complications. We therefore propose that in selected patients, the endoscopic transnasal approach is an effective, safe and minimally invasive approach for the removal of intraorbital intraconal foreign bodies. The intraoperative use of a magnet can facilitate the successful location and removal of magnetic metallic foreign bodies. Address correspondence and reprint requests to Jianfeng Liu, MD, Department of Otolaryngology, China-Japan Friendship Hospital, Yinghuadong Street, Chaoyang District, Beijing, China 100029; e-mail: mmconfucius@163.com Received 19 February, 2019 Accepted 31 March, 2019 The authors report no conflicts of interest. Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Web site (www.jcraniofacialsurgery.com). © 2019 by Mutaz B. Habal, MD.