Magnetic Resonance Materials in Physics, Biology and Medicine

Projection-based respiratory-resolved left ventricular volume measurements in patients using free-breathing double golden-angle 3D radial acquisition

Abstract

Objective

To refine a new technique to measure respiratory-resolved left ventricular end-diastolic volume (LVEDV) in mid-inspiration and mid-expiration using a respiratory self-gating technique and demonstrate clinical feasibility in patients.

Materials and methods

Ten consecutive patients were imaged at 1.5 T during 10 min of free breathing using a 3D golden-angle radial trajectory. Two respiratory self-gating signals were extracted and compared: from the k-space center of all acquired spokes, and from a superior–inferior projection spoke repeated every 64 ms. Data were binned into end-diastole and two respiratory phases of 15% respiratory cycle duration in mid-inspiration and mid-expiration. LVED volume and septal–lateral diameter were measured from manual segmentation of the endocardial border.

Results

Respiratory-induced variation in LVED size expressed as mid-inspiration relative to mid-expiration was, for volume, 1 ± 8% with k-space-based self-gating and 8 ± 2% with projection-based self-gating (P = 0.04), and for septal–lateral diameter, 2 ± 2% with k-space-based self-gating and 10 ± 1% with projection-based self-gating (P = 0.002).

Discussion

Measuring respiratory variation in LVED size was possible in clinical patients with projection-based respiratory self-gating, and the measured respiratory variation was consistent with previous studies on healthy volunteers. Projection-based self-gating detected a higher variation in LVED volume and diameter during respiration, compared to k-space-based self-gating.

Realization of 19 F MRI oximetry method using perfluorodecalin

Abstract

Objective

To identify the technical aspects of the potential use of clinically approved perfluorodecalin (PFD, C10F18) for 19F magnetic resonance imaging (MRI) oximetry method at high magnetic field 7.05 T.

Materials and methods

19T1 measurements were made on a set of PFD samples with different oxygen contents (0%, 21%, and 100%) at room (21 °C) and body temperature (37 °C). In vivo MRI studies were carried out on one healthy rat and two rats with C6 brain glioma.

Results

The selective excitation of the magnetically equivalent 19F nuclei of CF2 groups of trans-isomer of PFD, which give a doublet at a frequency of about − 140 ppm (in relation the chemical shift of trifluoroacetic acid, which is − 76.55 ppm) should be done for correct implementation of 19F MRI oximetry method. The amount of PFD equal to 30 μl is the optimal for obtaining reliable data on the measured T1 values. In this case, the standard deviation of T1 does not exceed 5%. In vivo MRI studies showed that the values of the partial pressure of oxygen (pO2) decrease from normal values of about 38 mmHg (healthy brain) to almost 0 mmHg at the last stage of tumor growth.

Conclusion

The study showed the feasibility of the successful application of PFD for 19F MRI oximetry method.

Precision of T1-relaxation time measurements in the hepatic portal vein: influence of measurement technique and sequence parameters

Abstract

Objective

To investigate the effects of a range of parameter settings on T1 measurement stability in the portal vein using the T1-mapping sequences Look-Locker (LL) and Modified Look-Locker inversion recovery (MOLLI).

Materials and methods

Ten different versions of LL and MOLLI sequences were tested and compared to a reference sequence provided by the MR manufacturer. Ten healthy volunteers were imaged multiple times on two separate scan days at 3T. The mean T1 values and coefficient of variation (CoV) were calculated for each of the ten sequences and compared to the reference sequence.

Results

Six of the tested sequences had T1 values close to the reference sequence; among those, three sequences achieved lower CoV than the reference sequence. Lowest CoV was achieved using a non-triggered LL sequence with 5 beat readout and a 45o flip angle (mean T1 1733 ms ± 89 ms, CoV 1.3% ± 0.58%).

Conclusion

T1-measurements in the hepatic portal vein can be performed with high precision using either MOLLI or LL sequences provided that LL sampling duration is sufficiently long and flip angle sufficiently high. The advantage of constant timing outweighed the advantage of ECG-triggering.

A phase-cycled temperature-sensitive fast spin echo sequence with conductivity bias correction for monitoring of mild RF hyperthermia with PRFS

Abstract

Objective

Mild hyperthermia (HT) treatments are generally monitored by phase-referenced proton resonance frequency shift calculations. A novel phase and thus temperature-sensitive fast spin echo (TFSE) sequence is introduced and compared to the double echo gradient echo (DEGRE) sequence.

Theory and methods

For a proton resonance frequency shift (PRFS)-sensitive TFSE sequence, a phase cycling method is applied to separate even from odd echoes. This method compensates for conductivity change-induced bias in temperature mapping as does the DEGRE sequence. Both sequences were alternately applied during a phantom heating experiment using the clinical setup for deep radio frequency HT (RF-HT). The B0 drift-corrected temperature values in a region of interest around temperature probes are compared to the temperature probe data and further evaluated in Bland–Altman plots. The stability of both methods was also tested within the thighs of three volunteers at a constant temperature using the subcutaneous fat layer for B0-drift correction.

Results

During the phantom heating experiment, on average TFSE temperature maps achieved double temperature-to-noise ratio (TNR) efficiency in comparison with DEGRE temperature maps. In-vivo images of the thighs exhibit stable temperature readings of ± 1 °C over 25 min of scanning in three volunteers for both methods. On average, the TNR efficiency improved by around 25% for in vivo data.

Conclusion

A novel TFSE method has been adapted to monitor temperature during mild HT.

A study of within-subject reliability of the brain’s default-mode network

Abstract

Objective

Resting-state functional magnetic resonance imaging (fMRI) is promising for Alzheimer’s disease (AD). This study aimed to examine short-term reliability of the default-mode network (DMN), one of the main haemodynamic patterns of the brain.

Materials and methods

Using a 1.5 T Philips Achieva scanner, two consecutive resting-state fMRI runs were acquired on 69 healthy adults, 62 patients with mild cognitive impairment (MCI) due to AD, and 28 patients with AD dementia. The anterior and posterior DMN and, as control, the visual-processing network (VPN) were computed using two different methodologies: connectivity of predetermined seeds (theory-driven) and dual regression (data-driven). Divergence and convergence in network strength and topography were calculated with paired t tests, global correlation coefficients, voxel-based correlation maps, and indices of reliability.

Results

No topographical differences were found in any of the networks. High correlations and reliability were found in the posterior DMN of healthy adults and MCI patients. Lower reliability was found in the anterior DMN and in the VPN, and in the posterior DMN of dementia patients.

Discussion

Strength and topography of the posterior DMN appear relatively stable and reliable over a short-term period of acquisition but with some degree of variability across clinical samples.

The feasibility of a novel limited field of view spiral cine DENSE sequence to assess myocardial strain in dilated cardiomyopathy

Abstract

Objective

Develop an accelerated cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance (CMR) sequence to enable clinically feasible myocardial strain evaluation in patients with dilated cardiomyopathy (DCM).

Materials and methods

A spiral cine DENSE sequence was modified by limiting the field of view in two dimensions using in-plane slice-selective pulses in the stimulated echo. This reduced breath hold duration from 20RR to 14RR intervals. Following phantom and pilot studies, the feasibility of the sequence to assess peak radial, circumferential, and longitudinal strain was tested in control subjects (n = 18) and then applied in DCM patients (n = 29).

Results

DENSE acquisition was possible in all participants. Elements of the data were not analysable in 1 control (6%) and 4 DCM r(14%) subjects due to off-resonance or susceptibility artefacts and low signal-to-noise ratio. Peak radial, circumferential, short-axis contour strain and longitudinal strain was reduced in DCM patients (p < 0.001 vs. controls) and strain measurements correlated with left ventricular ejection fraction (with circumferential strain r = − 0.79, p < 0.0001; with vertical long-axis strain r = − 0.76, p < 0.0001). All strain measurements had good inter-observer agreement (ICC > 0.80), except peak radial strain.

Discussion

We demonstrate the feasibility of CMR strain assessment in healthy controls and DCM patients using an accelerated cine DENSE technique. This may facilitate integration of strain assessment into routine CMR studies.

Accelerated multi-contrast high isotropic resolution 3D intracranial vessel wall MRI using a tailored k-space undersampling and partially parallel reconstruction strategy

Abstract

Objective

To develop a 3D multi-contrast IVW protocol with 0.5-mm isotropic resolution and a scan time of 5 min per sequence.

Materials and methods

Pre-contrast T1w VISTA, DANTE prepared PDw VISTA, SNAP, and post-contrast T1w VISTA were accelerated using cartesian undersampling with target ordering method (CUSTOM) and self-supporting tailored k-space estimation for parallel imaging reconstruction (STEP). CUSTOM + STEP IVW was compared to full-sample IVW, SENSE-accelerated IVW, and CUSTOM + zero-filled Fourier reconstruction in normal volunteers and subjects with intracranial atherosclerotic disease (ICAD). Image quality, vessel delineation, CSF suppression, and blood suppression were compared.

Results

CUSTOM + STEP vessel wall delineation was comparable to full-sample IVW and better than SENSE IVW for vessel wall delineation on T1w VISTA and luminal contrast on SNAP. Average image quality and wall depiction were significantly improved using STEP reconstruction compared with zero-filled Fourier reconstruction, with no significant difference in CSF or blood suppression.

Conclusions

CUSTOM + STEP allowed multi-contrast 3D 0.5-mm isotropic IVW within 30 min. Although some quantitative and qualitative scores for CUSTOM − STEP were lower than fully sampled IVW, CUSTOM + STEP provided comparable vessel wall delineation as full-sample IVW and was superior to SENSE. CUSTOM + STEP IVW was well tolerated by patients and showed good delineation of ICAD plaque.

Feasibility of diffusion-weighted imaging with DWIBS in staging Hodgkin lymphoma in pediatric patients: comparison with PET/CT

Abstract

Objective

The aim of the study was to evaluate feasibility of diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) method in diagnosing Hodgkin lymphoma in pediatric patients and to compare it with 18F-FDG PET/CT as a gold standard.

Materials and methods

Eleven patients (median age 14) with newly diagnosed Hodgkin lymphoma were examined with 18F-FDG PET/CT and MRI including whole-body DWIBS sequence (b = 0, 800 s/mm2), before the oncologic treatment. About 26 locations of lymphatic tissues were evaluated visually and quantitatively using ADCmean (DWIBS) and SUVmax (18F-FDG PET/CT), respectively.

Results

All affected lymph node regions (n = 134) diagnosed in 18F-FDG PET/CT were found with DWIBS, presenting decreased diffusion. Significant correlation was found between ADC and SUV values (R2 = − 0.37; p = 0.0001). Nevertheless, additional 33 regions were recognized only by DWIBS. They were significantly smaller than regions diagnosed by both methods.

Discussion

Agreement between DWIBS and 18F-FDG PET/CT for detection and staging of malignant lymphoma is high. DWIBS can be used for the evaluation of pediatric Hodgkin lymphoma.

Challenges for labeling and longitudinal tracking of adoptively transferred autoreactive T lymphocytes in an experimental type-1 diabetes model

Abstract

Objective

Tracking the autoreactive T-cell migration in the pancreatic region after labeling with fluorinated nanoparticles (1,2-dioleoyl-sn-glycero-3-phosphoethanolamine-N-[3-(2-pyridyldithio)propionate]-perfluoro-15-crown-5-ether nanoparticles, PDP-PFCE NPs) in a diabetic murine model using 19F MRI.

Materials and methods

Synthesis of novel PDP-PFCE fluorine tracer was performed for in vitro labeling of T cells. Labeling conditions were optimized using different PDP-PFCE NPs concentrations. For in vivo 19F MRI, mice were longitudinally followed after adoptive transfer of activated, autoreactive, labeled T cells in NOD.SCID mice.

Results

Established MR protocols were used for challenging T cell labeling to track inflammation in a model of diabetes after successful labeling of CD4+ and CD8+ T cells with PDP-PFCE NPs. However, T cells were difficult to be detected in vivo after their engraftment in animals.

Discussion

We showed successful in vitro labeling of T cells using novel fluorinated liposomal nanoparticles. However, insufficient and slow accumulation of labeled T cells and subsequent T cell proliferation in the pancreatic region remains as limitations of in vivo cell imaging by 19F MRI.

In-bore biopsies of the prostate assisted by a remote-controlled manipulator at 1.5 T

Abstract

Purpose

To evaluate the technical and clinical utility of a fully MRI-compatible, pneumatically driven remote-controlled manipulator (RCM) for targeted biopsies of the prostate at 1.5 T.

Materials and methods

The data of the first 22 patients that were biopsied under robotic assistance were analyzed. Interventional planning relied on T2-weighted (T2w) turbo spin-echo (TSE) images (axial and sagittal) with a high-b-value diffusion-weighted acquisition added in selected cases. Alignment of the needle guide was controlled with a short balanced SSFP sequence in two oblique planes along the MR-visible sheath. Signals were acquired with a combination of elements from a 30-channel body and a 32-channel spine coil. Biopsy samples were taken with a fully automatic 18-G biopsy gun with a length of 150 or 175 mm.

Results

Mean age was 66.6 years and average PSA level was 11.5 ng/ml. Fourteen out of 22 patients (63%) had received prior biopsies under transrectal ultrasound guidance. Diagnostic MRI reports (before biopsy) involved 17 cases with a single suspicious finding (four PI-RADS 3, one PI-RADS 3–4, eight PI-RADS 4 and nine PI-RADS 5 cases). The median effective procedure time was 33.9 (range 25.0–55.9) min for 16 cases with one CSR and 63.4 (52.7–81.8) min for 5 cases with two CSRs. The biopsy with three CSRs took 74.0 min. Histopathologic examination revealed prostate cancer in 14 of 22 cases.

Conclusion

MR-targeted, transrectal biopsy of the prostate could be reliably performed with a robotic manipulator at a field strength of 1.5 T. Balanced SSFP imaging is considered a viable option for fast procedural control. Follow-up work needs to evaluate to what extent in-bore adjustments and workflow enhancements will contribute to shorter procedure times or higher patient comfort.