Improved Detection of Benign and Malignant Rib Lesions in the Routine Computed Tomography Workup of Oncological Patients Using Automated Unfolded Rib Image Postprocessing
Objective The aim of this study was to evaluate the performance of the automated computed tomography (CT) postprocessing software unfolded rib images for improved detection of both benign and malignant rib lesions during routine diagnostic workup of oncological patients. Materials and Methods One thousand eight in-patients and out-patients (63.66 ± 14.25 years; range, 18.67–95.67 years; 405 females and 603 males), undergoing chest CT between July 2018 to January 2019 at our institution, were retrospectively evaluated. Patients underwent chest CT alone or as part of a whole-body CT staging/restaging. The CT protocol consisted of the following: 120 kV; 100 mAs; matrix, 512 × 512; collimation, 0.6 mm; reconstructed section thickness of 3 mm and 1 mm using a soft tissue spatial resolution kernel (I30f) and a sharp kernel (B70f). Both transversal image data sets were used for “conventional” diagnosis including coronal reformates with 3-mm slice thickness. One-millimeter slice thickness image data sets of all patients were additionally directed from the scanner to a computational server where they were automatically postprocessed to 3-dimensional unfolded ribs. The “unfolding” of the rib using the centerline as an axis allows a synchronous display and rotation of all ribs by mouse scrolling. These postprocessed image data sets were evaluated in a separate reading session (approximately 4 weeks later). The readers had no information about the underlying medical history or clinical presentation. They were asked to record the lesion number, site of involvement along the rib (proximal, body, distal), number of the involved ribs, and the character of the lesion in terms of lytic versus sclerotic versus mixed lytic/sclerotic. The standard of reference was 18F-FDG PET, 68Ga-DOMITATE PET/CT, bone scan, or imaging follow-up (>6 months). Results From a total of 1008 evaluated patients, 763 (73.02%) were hemato-oncologic patients. A total of 104 rib lesions were found by transversal CT image reading, whereas the unfolded rib image reading detected 305 lesions. Eighty-nine were classified malignant, and 202 were classified benign. Detection of malignant rib lesions proved significant both for less than 1 cm (P < 0.02) and more than 1 cm in diameter (P < 0.007). The sensitivity, specificity, positive predictive value, and negative predictive value for detection of malignant rib lesions were 97.7%, 98.5%, 96.6%, and 99% for unfolding ribs, and 76.4%, 100%, 92.7%, and 90.5% for conventional (transversal) image reading, respectively. Detection of sclerotic rib lesions and lesions greater than 1 cm in diameter were significantly better (P < 0.01) for the unfolding rib algorithm. Conclusions The “unfolded rib” reformates are significantly superior for rib lesion detection compared with conventional transversal CT scan reading and should therefore be used in all patients, particularly those with an oncologic background. Received for publication April 29, 2019; and accepted for publication, after revision, June 17, 2019. Sorin Dumitru Ioanoviciu and Marius Horger both share equal contribution. Conflicts of interest and sources of funding: J.F. received institutional research support from Siemens Healthcare USA, DePuy, Zimmer, Microsoft, and BTG International, and is a scientific advisor of Siemens Healthcare USA, Alexion Pharmaceuticals, and BTG International. He also received speaker's honorarium from Siemens Healthcare USA and has shared patents with Siemens Healthcare and Johns Hopkins University. M.H. received institutional research support from Siemens Healthineers Germany; he is a scientific advisor of Siemens Healthineers Germany and received speaker's honorarium from Siemens Healthineers Germany. K.E., C.K., and S.D.I. have no conflicts of interest to declare. Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal’s Web site (www.investigativeradiology.com). Correspondence to: Kaspar Ekert, MD, Department of Radiology, Diagnostic and Interventional Radiology, Eberhard Karls University, Hoppe-Seyler-Straße 3, D-72076 Tübingen, Germany. E-mail: kaspar.ekert@uni-tuebingen.de. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Increased T1 Signal Intensity of the Anterior Pituitary Gland on Unenhanced Magnetic Resonance Images After Chronic Exposure to Gadodiamide
Objective The aim of this study was to assess the signal intensity of the anterior pituitary (AP) gland on unenhanced T1-weighted images in patients with history of serial intravenous injections of gadodiamide and normal renal function. Materials and Methods We included 53 patients who had undergone at least 5 injections of gadodiamide and a control group of 15 subjects who underwent at least 5 brain magnetic resonance imaging without gadolinium-based contrast agents. Using unenhanced sagittal T1-weighted images, values of mean signal intensity of the AP and of the central pons were obtained. Anterior pituitary–to–pons signal intensity ratios were calculated dividing the values of the AP by those of the pons. Then, the ratios were compared between the first and the last magnetic resonance imaging scans for all the subjects. To assess the difference between the first and the last ratios, nonparametric Wilcoxon signed-rank test with Monte Carlo resampling was applied. A P value less than 0.05 was considered as statistically significant. Results The comparison between the first and the last scan revealed a statistically significant increase of AP-to-pons ratio in the last scan for the gadolinium-exposed group (P < 0.001), whereas nonsignificant results were found for the control group (P = nonsignificant). Conclusions We found an increased signal intensity of the AP on unenhanced T1-weighted images in patients with history of serial intravenous injections of gadodiamide and normal renal function, suggesting gadolinium deposition or long-term retention within the AP gland. Our findings need to be confirmed by further histochemical analysis of AP gland tissue samples. Received for publication June 21, 2019; and accepted for publication, after revision, July 6, 2019. Conflicts of interest and sources of funding: none declared. Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal’s Web site (www.investigativeradiology.com). Correspondence to: Carlo A. Mallio, MD, Unit of Diagnostic Imaging and Interventional Radiology, Departmental Faculty of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy. E-mail: c.mallio@unicampus.it. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Transcranial Shear Wave Elastography of Neonatal and Infant Brains for Quantitative Evaluation of Increased Intracranial Pressure
Objectives Increased intracranial pressure (ICP) in neonates and infants is a severe disease state that requires adequate diagnosis and, depending on the clinical situation and whether it is increasing, a rapid and efficient therapy. Clinical evaluation, B-mode ultrasound, and Doppler ultrasound give rise to a basic noninvasive diagnosis of increased ICP. The purpose of this prospective study was 2-fold: first, to analyze the technical feasibility of obtaining shear wave elastography (SWE) measurements of an infant's brain, and second, to compare the values of healthy neonates to those who have hydrocephalus and are either suspected of having or invasively shown to have increased ICP. Materials and Methods This was a prospective, institutional review board–approved study of 184 neonates and infants with a mean age of 12 weeks (ranging from 1 day to 12 months). The final, technical evaluable cohort consisted of 166 infants, of whom 110 were healthy asymptomatic infants and 56 were diagnosed with hydrocephalus. Of the latter, 38 showed clinically increased ICP and 18 did not. Invasive ICP measurements were available from 47 of the children. All infants underwent systematic examination using B-mode ultrasound, Doppler ultrasound, and SWE using a high-resolution linear 15-MHz probe (Aixplorer; Supersonic), by 1 of 2 radiologists, each of whom had at least 5 years' experience examining children's brains and applying SWE. Semiquantitative and quantitative SWE measurements were performed. We compared the SWE values to each participant's clinical symptoms and to their invasive ICP measurement results. Correlations were calculated using Pearson and Spearman correlation coefficients. We used Student t test to compare the mean SWE values in healthy children to those of children with increased ICP. Results Shear wave elastography in the brain was technically feasible, giving reliable SWE measurements in 110 (88.7%) of 124 of healthy children and in 56 (93.3%) of 60 children with hydrocephalus. Shear wave elastography values and, thus, rigidity in the brain's parenchyma were significantly higher in children with hydrocephalus (n = 56) than in healthy children (n = 110; mean, 21.8 kPa vs 14.1 kPa; P = 0.0083). A thorough correlation between invasive ICP measurements and SWE values in a subgroup of patients with hydrocephalus revealed a direct correlation between increased ICP and increased SWE values (r = 0.69, P < 0.001). Mean SWE values were 30.8 kPa (range, 23.9–62.3 kPa) in patients with confirmed increased ICP (n = 35) versus 16.2 kPa (range, 10.2–41.9 kPa) in patients with nonincreased ICP (n = 12). Conclusions Shear wave elastography is feasible in neonates with increased ICP and could be a useful additional diagnostic imaging and monitoring method for children verified or suspected to have increased ICP. However, more evidence is necessary to further evaluate the usefulness of SWE measurements in neonates with hydrocephalus. Clinical Relevance Shear wave elastography can be used as a surrogate marker for ICP in neonates and infants. Received for publication April 25, 2019; and accepted for publication, after revision, June 23, 2019. Conflicts of interest and sources of funding: none declared. Correspondence to: Timm Dirrichs, MD, Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074 Aachen, Germany. E-mail: tdirrichs@ukaachen.de. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Tumor Contrast Enhancement and Whole-Body Elimination of the Manganese-Based Magnetic Resonance Imaging Contrast Agent Mn-PyC3A
Objectives The goals of this study were to compare the efficacy of the new manganese-based magnetic resonance imaging (MRI) contrast agent Mn-PyC3A to the commercial gadolinium-based agents Gd-DOTA and to Gd-EOB-DTPA to detect tumors in murine models of breast cancer and metastatic liver disease, respectively, and to quantify the fractional excretion and elimination of Mn-PyC3A in rats. Methods T1-weighted contrast-enhanced MRI with 0.1 mmol/kg Mn-PyC3A was compared with 0.1 mmol/kg Gd-DOTA in a breast cancer mouse model (n = 8) and to 0.025 mmol/kg Gd-EOB-DTPA in a liver metastasis mouse model (n = 6). The fractional excretion, 1-day biodistribution, and 7-day biodistribution in rats after injection of 2.0 mmol/kg [52Mn]Mn-PyC3A or Gd-DOTA were quantified by 52Mn gamma counting or Gd elemental analysis. Imaging data were compared with a paired t test; biodistribution data were compared with an unpaired t test. Results The postinjection-preinjection increases in tumor-to-muscle contrast-to-noise ratio (ΔCNR) 3 minutes after injection of Mn-PyC3A and Gd-DOTA (mean ± standard deviation) were 17 ± 3.8 and 20 ± 4.4, respectively (P = 0.34). Liver-to-tumor ΔCNR values at 8 minutes postinjection of Mn-PyC3A and Gd-EOB-DTPA were 28 ± 9.0 and 48 ± 23, respectively (P = 0.11). Mn-PyC3A is eliminated with 85% into the urine and 15% into the feces after administration to rats. The percentage of the injected doses (%ID) of Mn and Gd recovered in tissues after 1 day were 0.32 ± 0.12 and 0.57 ± 0.12, respectively (P = 0.0030), and after 7 days were 0.058 ± 0.051 and 0.19 ± 0.052, respectively (P < 0.0001). Conclusions Mn-PyC3A provides comparable tumor contrast enhancement to Gd-DOTA in a mouse breast cancer model and is more completely eliminated than Gd-DOTA; partial hepatobiliary elimination of Mn-PyC3A enables conspicuous delayed phase visualization of liver metastases. Received for publication April 16, 2019; and accepted for publication, after revision, May 22, 2019. Conflicts of interest and sources of funding: This work was supported by grants from the National Institutes of Health (K25HL128899, R21EB022804, R44DK113906, P41RR014075, R01EB009062, and S10OD010650) and the Department of Energy (DESC0015773). P.C. and E.M.G. hold equity and consult to Reveal Pharmaceuticals, a company that is working to develop a manganese-based MRI contrast agent. The other authors report no conflicts of interest. Correspondence to: Eric M. Gale, PhD, Athinoula A. Martinos Center for Biomedical Imaging, 149 Thirteenth St, Suite 2301, Charlestown, MA 02129. E-mail: egale@nmr.mgh.harvard.edu. Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal’s Web site (www.investigativeradiology.com). Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Breast Magnetic Resonance Spectroscopy at 3 T in Biopsy-Proven Breast Cancers: Does Choline Peak Correlate With Prognostic Factors?
Objectives The role of functional techniques, such as magnetic resonance spectroscopy (1H-MRS), as noninvasive tools to increase breast MR imaging reliability has been widely investigated during the last 2 decades. Considering the growing interest in tumor biology and its influence on functional parameters, the aim of this study was to investigate the relationship between 1H-MRS parameters and breast cancer biomarkers and to evaluate whether the results of 1H-MRS at 3 T can correlate with established breast cancer prognostic factors in our clinical experience. Materials and Methods One hundred two patients with biopsy-proven breast cancer underwent 3 T breast MR imaging. Single-voxel 1H-MRS was performed after the T1-weighted sequence, using a PRESS water-suppressed sequence (BREASE). Data were collected from a single rectangular volume of interest that encompassed the lesion. Magnetic resonance images and spectra of 102 Breast Imaging Reporting and Data System 6 lesions were prospectively evaluated by 2 radiologists in consensus. 1H-MRS results were considered positive if the choline peak signal-to-noise ratio was 2 or higher. 1H-MRS findings were then compared with morphological features and to histological findings, such as lesion size, nuclear grade, Ki-67, hormone receptor status, and Her2 expression. Results Elevated levels of total choline were detectable in 68/102 cases (66.67%) and undetectable in 34/102 (33.33%). A statistically significant association between the presence of choline peak and higher tumor grading (P < 0.0001), greater Ki-67 value (P < 0.0001), and larger lesion size (P < 0.0001) was found. No statistically significant associations were observed between choline peak and the luminal subgroups, even if higher levels of choline were more frequent in nonluminal A lesions. Conclusions Our study confirms that 3 T breast 1H-MRS can be a valid additional tool to obtain further information about breast cancer biology and to predict tumor aggressiveness, because the detection of elevated levels of total choline in the spectrum is associated with a biologically aggressive breast cancer phenotype (large dimensions, grade 3, high values of Ki-67). Our results need to be validated in standardized larger-scale studies. Received for publication April 29, 2019; and accepted for publication, after revision, June 15, 2019. Conflicts of interest and sources of funding: This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors, including National Institutes of Health, Wellcome Trust, and Howard Hughes Medical Institute. The authors report no conflicts of interest. Correspondence to: Francesca Galati, MD, PhD, Department of Radiological, Oncological and Pathological Sciences, “Sapienza”–University of Rome, V.le Regina Elena, 324, 00161 Rome, Italy. E-mail: francesca.galati3@gmail.com. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Modulating Diffusion-Weighted Magnetic Resonance Imaging for Screening in Oncologic Tertiary Prevention: A Prospective Ex Vivo and In Vivo Study
Introduction Diffusion-weighted imaging (DWI) is an important part of oncological magnetic resonance imaging (MRI) examinations, especially for tertiary cancer prevention in terms of early detection of recurrent disease. However, abdominal studies can be challenged by motion artifacts, poor signal-to-noise ratios, and visibility of retroperitoneal structures, which necessitates sequence optimization depending on the investigated region. This study aims at prospectively evaluating an adapted DWI sequence ex vivo and in vivo in oncologic patients undergoing abdominal MRI. Methods This institutional review board–approved, prospective study included phantom measurements, volunteer examinations, and oncologic patient examinations of the abdomen. Fifty-seven MRI examinations in 54 patients (mean age, 58 years; range, 21–90 years) were included into the analysis. The MRI examination were performed at a 1.5 T MRI scanner (MAGNETOM Aera; Siemens Healthcare, Erlangen, Germany) and included both a standard EPI-DWI (s-DWI; b = 50, 900 s/mm2) and an adapted DWI (opt-DWI; EPI-DWI with b = 0, 50, 900, 1500 s/mm2, acquisition with higher spatial resolution and optimized processing for the abdomen including motion correction, adaptive image combination, and background suppression). For b = 900 s/mm2, the ratio of signal intensity in the normal tissue and the standard deviation of the noise in the surrounding air was quantitatively calculated; image quality and tissue differentiation parameters were rated by 2 independent, blinded readers using a 5-point Likert scale. Statistics included Wilcoxon signed-rank test and kappa statistic (P < 0.05/0.0125 after Bonferroni correction). Results The DWI phantom demonstrated an optimized contour sharpness and inlay differentiation for opt-DWI. The apparent ratio of normal tissue signal/standard deviation of background noise at b = 900 s/mm2 of the right/left hemiabdomen was significantly increased in opt-DWI (mean, 71.9 ± 23.5/86.0 ± 43.3) versus s-DWI (mean, 51.4 ± 15.4/63.4 ± 36.5; P < 0.001). Image quality parameters (contour sharpness and tissue differentiation of upper abdominal and retroperitoneal structures) were significantly increased in opt-DWI versus s-DWI (P < 0.001). Interreader reliability test showed good agreement (kappa = 0.768; P < 0.001). Discussion This study prospectively evaluated the potential of adapted DWI for screening in tertiary prevention of oncologic patients. An optimized DWI protocol with advanced processing achieved improved image quality in quantitative and qualitative analyses. Oncological optimization of DWI should be performed before its application in cancer patients to improve both screening and follow-up examinations, to better unleash the diagnostic potential of DWI. Received for publication April 2, 2019; and accepted for publication, after revision, May 25, 2019. Conflicts of interest and sources of funding: S.B. received speaker's fee from Siemens, pending patents in DWI; T.A.K. is a cofounder of HQ Imaging GmbH, pending patents in DWI. F.B.L. is a cofound of HQ Imaging GmbH. T.B., D.N, and R.S. are employees of Siemens. No funding was declared. Correspondence to: Constantin Dreher, MD, Department of Radiology (E010), German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany. E-mail: c.dreher@dkfz.de. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Measuring Dynamic CT Perfusion Based on Time-Resolved Quantitative DECT Iodine Maps: Comparison to Conventional Perfusion at 80 kVp for Pancreatic Carcinoma
Objectives Using dual-energy computed tomography (DECT) for quantifying iodine content after injection of contrast agent could provide a quantitative basis for dynamic computed tomography (CT) perfusion measurements by means of established mathematical models of contrast agent kinetics, thus improving results by combining the strength of both techniques, which was investigated in this study. Materials and Methods A dynamic DECT acquisition over 51 seconds performed at 80/Sn140 kVp in 17 patients with pancreatic carcinoma was used to calculate iodine-enhancement images for each time point by means of 3-material decomposition. After motion correction, perfusion maps of blood flow were calculated using the maximum-slope model from both 80 kVp image data and iodine-enhancement images. Blood flow was measured in regions of interest placed in healthy pancreatic tissue and carcinoma for both of the derived perfusion maps. To assess image quality of input data, an adjusted contrast-to-noise ratio was calculated for 80 kVp images and iodine-enhancement images. Susceptibility of perfusion results to residual patient breathing motion during acquisition was investigated by measuring blood flow in fatty tissue surrounding the pancreas, where blood flow should be negligible compared with the pancreas. Results For both 80 kVp and iodine-enhancement images, blood flow was significantly higher in healthy tissue (114.2 ± 37.4 mL/100 mL/min or 115.1 ± 36.2 mL/100 mL/min, respectively) than in carcinoma (46.5 ± 26.6 mL/100 mL/min or 49.7 ± 24.7 mL/100 mL/min, respectively). Differences in blood flow between 80 kVp image data and iodine-enhancement images were statistically significant in healthy tissue, but not in carcinoma. For 80 kVp images, adjusted contrast-to-noise ratio was significantly higher (1.3 ± 1.1) than for iodine-enhancement images (1.1 ± 0.9). When evaluating fatty tissue surrounding the pancreas for estimating influence of patient motion, measured blood flow was significantly lower for iodine-enhancement images (30.7 ± 12.0 mL/100 mL/min) than for 80 kVp images (39.0 ± 19.1 mL/100 mL/min). Average patient radiation exposure was 8.01 mSv for dynamic DECT acquisition, compared with 4.60 mSv for dynamic 80 kVp acquisition. Discussion Iodine enhancement images can be used to calculate CT perfusion maps of blood flow, and compared with 80 kVp images, results showed only a small difference of 1 mL/100 mL/min in blood flow in healthy tissue, whereas patient radiation exposure was increased for dynamic DECT. Perfusion maps calculated based on iodine-enhancement images showed lower blood flow in fatty tissues surrounding the pancreas, indicating reduced susceptibility to residual patient breathing motion during the acquisition. Received for publication March 27, 2019; and accepted for publication, after revision, May 17, 2019. Conflicts of interest and sources of funding: none declared. Correspondence to: Wolfram Stiller, PhD, Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120 Heidelberg, Germany. E-mail: wolfram.stiller@med.uni-heidelberg.de. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Improved Liver Diffusion-Weighted Imaging at 3 T Using Respiratory Triggering in Combination With Simultaneous Multislice Acceleration
Objectives The aim of this study was to retrospectively compare optimized respiratory-triggered diffusion-weighted imaging with simultaneous multislice acceleration (SMS-RT-DWI) of the liver with a standard free-breathing echo-planar DWI (s-DWI) protocol at 3 T with respect to the imaging artifacts inherent to DWI. Materials and Methods Fifty-two patients who underwent a magnetic resonance imaging study of the liver were included in this retrospective study. Examinations were performed on a 3 T whole-body magnetic resonance system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). In all patients, both s-DWI and SMS-RT-DWI of the liver were obtained. Images were qualitatively evaluated by 2 independent radiologists with regard to overall image quality, liver edge sharpness, sequence-related artifacts, and overall scan preference. For quantitative evaluation, signal-to-noise ratio was measured from signal-to-noise ratio maps. The mean apparent diffusion coefficient (ADC) was measured in each liver quadrant. The Wilcoxon rank-sum test was used for analysis of the qualitative parameters and the paired Student t test for quantitative parameters. Results Overall image quality, liver edge sharpness, and sequence-related artifacts of SMS-RT-DWI received significantly better ratings compared with s-DWI (P < 0.05 for all). For 90.4% of the examinations, both readers overall preferred SMS-RT-DWI to s-DWI. Acquisition time for SMS-RT-DWI was 34% faster than s-DWI. Signal-to-noise ratio values were significantly higher for s-DWI at b50 but did not statistically differ at b800, and they were more homogenous for SMS-RT-DWI, with a significantly lower standard deviation at b50. Mean ADC values decreased from the left to right hepatic lobe as well as from cranial to caudal for s-DWI. With SMS-RT-DWI, mean ADC values were homogeneous throughout the liver. Conclusions Optimized, multislice, respiratory-triggered DWI of the liver at 3 T substantially improves image quality with a reduced scan acquisition time compared with s-DWI. Received for publication April 15, 2019; and accepted for publication, after revision, May 22, 2019. Conflicts of interest and sources of funding: none declared. Correspondence to: Andrej Tavakoli, MD, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim, Germany. E-mail: s.tavakoli@gmx.de. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Three Tesla 3D High-Resolution Vessel Wall MRI of the Orbit may Differentiate Arteritic From Nonarteritic Anterior Ischemic Optic Neuropathy
Background Anterior ischemic optic neuropathy (AION) is the most common cause of acute optic neuropathy in older patients. Distinguishing between arteritic AION (A-AION) and nonarteritic (NA-AION) is paramount for improved patient management. Purpose The aim of this study was to evaluate 3-dimensional high-resolution vessel wall (HR-VW) magnetic resonance imaging (MRI) at 3 T to discriminate A-AION from NA-AION. Materials and Methods This prospective single-center study was approved by a national research ethics board and included 27 patients (17 A-AION and 10 NA-AION) with 36 AIONs from December 2014 to August 2017 who underwent 3 T HR-VW MRI. Two radiologists blinded to clinical data individually analyzed the imaging separately and in random order. Discrepancies were resolved by consensus with a third neuroradiologist. The primary diagnostic criterion was the presence of inflammatory changes of the ophthalmic artery. Secondary diagnostic criteria included the presence of an enhancement of the optic nerve or its sheath, the optic disc, or inflammatory changes of posterior ciliary or extracranial arteries. A Fisher exact test was used to compare A-AION from NA-AION patients. Results Inflammatory changes of the ophthalmic artery were present in all patients with A-AION but in none of NA-AION (P < 0.0001). Its sensitivity, specificity, positive predictive value, and negative predictive value were 100%. Inflammatory changes of posterior ciliary arteries were significantly more likely in A-AOIN (82% vs 0%, P < 0.0001). Interreader and intrareader agreements were almost perfect (κ = 0.82–1). Conclusions High-resolution vessel wall MRI seems highly accurate when distinguishing A-AION from NA-AION and might be useful to improve patient management. Received for publication April 8, 2019; and accepted for publication, after revision, June 1, 2019. Conflicts of interest and sources of funding: none declared. Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal’s Web site (www.investigativeradiology.com). Correspondence to: Augustin Lecler, MD, PhD, Department of Neuroradiology, Foundation Adolphe de Rothschild Hospital, 29 Rue Manin, 75019 Paris, France. E-mail: alecler@for.paris. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
Ultrasound Time-Harmonic Elastography of the Aorta: Effect of Age and Hypertension on Aortic Stiffness
Objectives The aim of this study was to investigate ultrasound time-harmonic elastography for quantifying aortic stiffness in vivo in the context of aging and arterial hypertension. Materials and Methods Seventy-four participants (50 healthy participants and 24 participants with long-standing hypertension) were prospectively included between January 2018 and October 2018, and underwent ultrasound time-harmonic elastography of the upper abdominal aorta. Compound maps of shear-wave speed (SWS) as a surrogate of tissue stiffness were generated from multifrequency wave fields covering the full field-of-view of B-mode ultrasound. Blood pressure and pulse wave velocity were measured beforehand. Interobserver and intraobserver agreement was determined in 30 subjects. Reproducibility of time-harmonic elastography was assessed in subgroups with repeated measurements after 20 minutes and after 6 months. Linear regression analysis, with subsequent age adjustment of SWS obtained, receiver operating characteristic analysis, and intraclass correlation coefficients (ICCs) were used for statistical evaluation. Results Linear regression analysis revealed a significant effect of age on SWS with an increase by 0.024 m/s per year (P < 0.001). Age-adjusted SWS was significantly greater in hypertensives (0.24 m/s; interquartile range [IQR], 0.17–0.40 m/s) than in healthy participants (0.07 m/s; IQR, −0.01 to 0.06 m/s; P < 0.001). A cutoff value of 0.15 m/s was found to differentiate best between groups (area under the receiver operating characteristic curve, 0.966; 95% confidence interval, 0.93–1.0; P < 0.001; 83% sensitivity and 98% specificity). Interobserver and intraobserver variability was excellent (ICC, 0.987 and 0.937, respectively). Reproducibility was excellent in the short term (ICC, 0.968; confidence interval, 0.878–0.992) and good in the long term (ICC, 0.844; confidence interval, 0.491–0.959). Conclusions Ultrasound time-harmonic elastography of the upper abdominal aorta allows quantification of aortic wall stiffness in vivo and shows significantly higher values in patients with arterial hypertension. Received for publication February 6, 2019; and accepted for publication, after revision, May 10, 2019. Conflicts of interest and sources of funding: This study was in part funded by a research grant from the German Research Foundation (Bonn, Germany) to Thomas Elgeti (grant number: EL606/2-1). The authors gratefully acknowledge support from the German Research Foundation (GRK2260 BIOQIC, SFB1340 Matrix-in-Vision). Supplemental digital contents are available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal’s Web site (www.investigativeradiology.com). Correspondence to: Thomas Elgeti, MD, Department of Radiology, Charité–Universitätsmedizin Berlin, Hindenburgdamm 30, 12203 Berlin, Germany. E-mail: thomas.elgeti@charite.de. Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.